Mohanty, MAnilkumar, TVMohanan, PVMuraleedharan, CVBhuvaneshwar, GSDerangere, FSampeur, YSuryanarayanan, R2012-12-042012-12-042002BIOMOLECULAR ENGINEERING. 19; 40945; 125-128http://dx.doi.org/10.1016/S1389-0344(02)00026-6http://www.ncbi.nlm.nih.gov/pubmed/12202172https://dspace.sctimst.ac.in/handle/123456789/705Diamond like carbon (DLC) coatings were deposited on to Ti substrates by plasma enhanced chemical vapor deposition technique. Ti and DLC/Ti samples were implanted in skeletal muscle of rabbits. The samples were explanted after 1, 3, 6 and 12 months and the tissue-cell interaction was studied. Our data indicate both DLC/Ti and bare Ti to be compatible with skeletal muscle. (C) 2002 Elsevier Science B.V. All rights reserved.BiocompatibilityLong term tissue response to titanium coated with diamond like carbon