Rajesh, P.Muraleedharan, CVKomath, ManojVarma, Harikrishna2012-12-042012-12-042011JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE. 22; 3; 497-505http://dx.doi.org/10.1007/s10856-011-4230-xhttps://dspace.sctimst.ac.in/handle/123456789/956Pulsed laser deposition (PLD) has been used to deposit hydroxyapatite (HA) ceramic over titanium substrate with an interlayer of titania. PLD has been identified as a potential candidate for bioceramic coatings over metallic substrates to be used as orthopedic and dental implants because of better process control and preservation of phase identity of the coating component. However, direct deposition of hydroxyapatite on titanium at elevated temperature results in the formation of natural oxide layer along with some perovskites like calcium titanate at the interface. This leads to easy debonding of ceramic layer from the metal and thereby affecting the adhesion strength. In the present study, adherent and stable HA coating over Ti6Al4V was achieved with the help of an interlayer of titania. The interlayer was made to a submicron level and HA was deposited consecutively to a thickness of around one micron by exposing to laser ablation at a substrate temperature of 400A degrees C. The deposited phase was identified to be phase pure HA by X-ray diffraction, scanning electron microscopy, energy dispersive X-ray analysis, and inductively coupled plasma spectrometry. The mechanical behavior of coating evaluated by scratch test indicates that the adhesion strength of HA coating was improved with the presence of titania interlayer.BiomaterialsPulsed laser deposition of hydroxyapatite on titanium substrate with titania interlayer