MODIFIED CROSSOVER AND GUIDEWIRE LOOP TECHNIQUE FOR DOUBLE-BALLOON ANGIOPLASTY OF THE AORTIC BIFURCATION
dc.contributor | GUPTA, AK | |
dc.contributor | RAVIMANDALAM, K | |
dc.contributor | RAO, VRK | |
dc.contributor | JOSEPH, S | |
dc.contributor | UNNI, M | |
dc.contributor | RAO, AS | |
dc.date.accessioned | 2012-12-04T11:44:38Z | |
dc.date.available | 2012-12-04T11:44:38Z | |
dc.date.issued | 1994 | |
dc.description.abstract | A modified form of crossover railroad technique is described for iliac and aortic bifurcation obstructions in which the iliac occlusion is crossed from the opposite side by a guidewire which is brought out through the ipsilateral puncture site. After forming a loop in the abdominal aorta, dilatation with two balloons is performed. This procedure was successfully performed in 2 patients having iliac artery occlusions and aortic bifurcation obstruction. | |
dc.identifier.citation | CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. 17; 2; 116-118 | en_US |
dc.identifier.uri | https://dspace.sctimst.ac.in/handle/123456789/752 | |
dc.publisher | CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY | |
dc.subject | Radiology | |
dc.title | MODIFIED CROSSOVER AND GUIDEWIRE LOOP TECHNIQUE FOR DOUBLE-BALLOON ANGIOPLASTY OF THE AORTIC BIFURCATION |