MODIFIED HYDROXYAPATITE MICROSPHERES AS IMMUNOADSORBENT FOR PLASMA PERFUSION - PRELIMINARY-STUDY

No Thumbnail Available
Date
1995
Journal Title
Journal ISSN
Volume Title
Publisher
JOURNAL OF COLLOID AND INTERFACE SCIENCE
Abstract
An improved solid-support, affinity immunoadsorbent suitable for extracorporeal perfusion of plasma is reported. This consists of hydroxyapatite microspheres coated with a thin layer of poly(vinyl alcohol) and immobilized phenylalanine as ligand. This adsorbent can remove IgG immunoglobulins specifically from plasma. The modified adsorbent may be used for direct hemoperfusion as a cheaper alternative to plasma adsorption therapy by eliminating cell separator for selective removal of antibodies belonging to immunoglobulin G class. (C) 1995 Academic Press, Inc.
Description
Keywords
Chemistry
Citation
174 ,1;224-229
Collections