Development of silastic polyurethane (Angioflex) materials with antibacterial agent

No Thumbnail Available
Date
1996
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
JOURNAL OF BIOMATERIALS APPLICATIONS
Abstract
Bioimplants incorporated with antimicrobial agents are needed to control Foreign Body Associated Infection (FBAI) in clinical settings. Attempts are made here to develop five different types of polyurethane (Angioflex), viz., (1) bare polymer, (2) bare polymer glow discharged, (3) bare polymer coated with chlorhexidine, (4) chlorhexidine coated polymer glow discharged, and (5) material (4) recoated with another layer of chlorhexidine digluconate. These materials are tested for their in vitro antibacterial effects using disc diffusion technique against five different standard clinical staphylococcus strains, viz., Wood 46 (Staph. aureus), A 182 (Staph. epidermidis), A 313 (Staph. epidermidis), A 61 (Staph. epidermidis), and A 72 (Staph. epidermidis). Maximum antibacterial effects (zone of inhibition) are observed with polyurethanes incorporated with chlorhexidine digluconate (3) and chlorhexidine incorporated and glow discharged (4). Findings of this study indicate that glow discharge does not seem to produce either additive or synergistic antibacterial effects with chlorhexidine digluconate coated Angioflex material.
Description
Keywords
Biomaterials
Citation
JOURNAL OF BIOMATERIALS APPLICATIONS. 10; 3; 210-216
Collections